Air bellow: installation & operation instructions
The following instructions should be taken into consideration when designing and fitting, what will lead to obtain the maximum benefits and performance of the Oria air bellows.
PRESSURE
The maximum allowable pressure during operation when using a standard construction air spring is 8 bar pressure. In case of being required a greater pressure, it should be consulted to the manufacturer or distributor.
Oria air bellows can be supplied with an alternative four-ply construction (high strength construction). The advantage of the four-ply version air actuator is that it is able to work with higher pressures, achieving greater forces. Basically, the four-ply air bellow has a pressure capability of 12 bar.
RETURN
An air spring is a single acting actuator that must never be used below atmospheric pressure. The return operation must be carried by external loads.
Please check the over-pressure in case of fast compression.
WORKING MEDIA
The air springs have been designed to work with compressed air. However, they can also work with nitrogen, oil, water and compressed air containing oil. In case of working with water, stainless steel metal parts are required to avoid corrosion.
SAFETY STOPS
Provide stroke limitations to prevent the air actuator exceeding the maximum allowable working height or to bottom out.
When working as a vibration air isolator, it allows motion in all directions, so horizontal stops constructed flexibly are recommended to achieve full isolation effect.
The amplitude of start-up and shutdown must be considered when designing the stops.
Air bellows must not be pressurized unless they are restricted by a suitable load or a stop.
SUPPORT AREA
The complete area of the rubber actuator should be used to ensure a uniform load distribution and bear the forces. If not possible, it is recommended to use at least a 65% of the support area.
INSTALLATION SPACE
It’s important to locate the air bellow in the right position and with the required space to ensure that it is going to work correctly and safely. Make sure there are no sharp materials or surfaces that could rub and damage the rubber bellow and that the air bellow, at maximum diameter, has enough clearance to avoid chafing.
ELASTOMER COMPOUND
The air bellows may be manufactured in different types of elastomer compounds, depending on the applications requirements.
• Natural (NR/SBR): Temperature range from -40° to +70°C. Standard material with excellent universal properties and very high dynamic capability.
• Clorobutyl (CIIR): Temperature range from -30 to +115°C. Highly used material due to its outstanding resistance to acids.
• Nitrile (NBR): Temperature range from -25° to +110°C. Excellent resistance to oils, fuels, ozone and outdoors.
• Ethylene Propylene Diene (EPDM): Temperature range from -20° to +115°C. Excellent resistance to high temperatures, ozone and outdoors.
• Chloroprene (CR): Temperature range from -20° to +110°C. Excellent weathering resistant and medium resistance to oils.
METALLIC PARTS
The metallic parts of the air bellows can be supplied in different qualities. The standard in most air springs is the electro galvanized steel, but they can also be supplied in stainless steel AISI-304, with high wear resistance and durability for media such as acids, chemicals and cleaning agents. Other stainless steel qualities as AISI-316L available upon request.
AUXILIARY RESERVOIR
The addition of an auxiliary reservoir increases the volume, decreasing the natural frequency of the air spring and so improving the isolation rate. To be effective, it is necessary to be located as close as possible and the connection pipes must allow an important flow.
TIGHTENING TORQUE
The maximum recommended tightening torques are the following:
| FASTENER TYPE | MAX. TORQUE [nm] |
|---|---|
| 41/2” Ref. – M6 Threads | 10 |
| 6” Aluminium Ref. – M8 Threads | 12 |
| M8 & M10 & 3/8-16 UNC Blind nut | 25 |
| M10 Studs | 25 |
| M8x1.0 Countersunk Bead Ring Bolts | 30 |
| M8 & M10 Socket Head Bead Ring Bolts | 40 |
| M8 & M10 Threaded Bead Ring Threads | 40 |
| G1/4” & 1/4” NPT Air Inlet Thread | 25 |
| G1/2” Air Inlet Thread | 25 |
| G3/4” & 3/4” NPT Air Inlet Thread | 50 |
STABILITY AND HEIGHT OF THE CENTRE OF GRAVITY
For an optimized stability of the machine, in order to minimize wobbling and optimize its isolation, the distance between the narrowest point of the mounted air bellows should be at least twice the height distance from the gravity centre.
If the system does not fulfil the requirement, stability can be improved by increasing the width of the base, elevating the mounting location, or adding an inertia base to shorten the centre of the gravity height.
LATERAL MISALIGNEMENT
Due to their flexibility, the air actuators can achieve different ranges of lateral misalignments. It depends on the size and construction, but a general rule of maximum admissible lateral misalignments is detailed below:
| NUMBER OF CONVOLUTION | MAX. LATERAL MISALIGNMENT [mm] |
|---|---|
| Single convolution bellows | 10 mm |
| Double convolution bellows | 20 mm |
| Triple convolution bellows | 30 mm |
Never use the air bellows in torsion.
LATERAL STIFFNESS
The lateral stiffness differs depending on factors such as number of plies (construction), height and pressure. For vibration isolation, it is recommended to use the air spring in the design height, as in this height the product reaches the maximum lateral rate or stability.
In the design height, single convolution and double convolution air springs have a rule of lateral stiffness 5% to 50% of the vertical stiffness, reaching the highest value of the vertical stiffness of 50% only in the larger high strength construction air springs.
| NUMBER OF CONVOLUTION | % |
|---|---|
| Single convolution bellows | 30% to 50% |
| Double convolution bellows | 5% to 30% |
| Triple convolution bellows | -* |
*The triple convolution air bellows, since they are laterally unstable, can only be used for vibration isolation with lateral guidance.
The lateral rate decreases as the air bellow height shortens.
ANGULAR CAPABILITY
The air bellows have an angular capability up to 25°. A general rule of maximum tilt angle is detailed the following chart:
| NUMBER OF CONVOLUTION | MAX. ANGULAR CAPABILITY [º] |
|---|---|
| Single convolution bellows | 10º – 15º |
| Double convolution bellows | 25º |
| Triple convolution bellows | 15º |
The maximum tilt angle will be in a certain stroke, so it must be checked:
- The highest point (h2 ) must be lower than the maximum height.
- The lowest point (h1 ) must be higher than the minimum height.

To determine the force of the air bellow, take the load of the height from the centre of the tilted plate.
Avoid chaffing of the most compressed part of the air actuator. It is not possible to combine angular misalignment with lateral misalignment.
Air bellow: maintenance & inspection instructions
Even as the Oria air bellows are designed to provide a long-term and trouble-free service, a regular maintenance is always highly recommended. Taking into account the following aspects will help avoiding a premature failure due to incorrect installation, lack of maintenance or other associated problems.
Before installing the rubber bellow in the application, an analysis of the replaced one should be performed to determine the cause of the failure. If the failure has been premature, the origin of the malfunction must be detected and solved in order to avoid the same failure in the newly installed rubber actuator.
CLEANING
Cleaning the rubber bellow is a very relevant aspect in the maintenance process. This is necessary to avoid the metal parts being rusted and also to prevent damages in the rubber bellows from aggressive substances. This will entail an increase of the life cycle of the industrial air bellow.
Clean the air bellow with water, soap or alcohol (methyl, ethyl or isopropyl). Do not use any abrasives, organic solvents, petrochemical or a direct pressurized steam cleaning system .
RUBBER BELLOW INSPECTION
Inspect the rubber bellow outer surface to check possible wears, cracks or damaged areas.
PNEUMATIC COMPONENTS INSPECTION
Inspect the pneumatic components connected to the air spring (valves, air pipes, regulators etc.) to replace them if required.
CONNECTIONS TIGHTENING
It is recommended to check the tightness of all the system, re-torquing if loose but never over-tightening.
The maximum recommended tightening torques are indicated in the installation section.
STORAGE
The rubber bellows stocked in the warehouse should not be exposed or located in high or very low temperature environments. Rubber bellows should be stored in cool, dark and dry conditions away from direct sunlight or ozone producing equipment (see ISO 2230).
*Note: For additional Technical support, please, check the enquiries with the manufacturer or local distributor. Additional Technical information and cross references are available in the website or upon request.